CVE-2017-5217 | Installing a zero-permission Android application on certain Samsung Android devices with KK(4.4), L(5.0/5.1), and M(6.0) software can continually crash the system_server process in the Android OS. The zero-permission app will create an active install session for a separate app that it has embedded within it. The active install session of the embedded app is performed using the android.content.pm.PackageInstaller class and its nested classes in the Android API. The active install session will write the embedded APK file to the /data/app directory, but the app will not be installed since third-party applications cannot programmatically install apps. Samsung has modified AOSP in order to accelerate the parsing of APKs by introducing the com.android.server.pm.PackagePrefetcher class and its nested classes. These classes will parse the APKs present in the /data/app directory and other directories, even if the app is not actually installed. The embedded APK that was written to the /data/app directory via the active install session has a very large but valid AndroidManifest.xml file. Specifically, the AndroidManifest.xml file contains a very large string value for the name of a permission-tree that it declares. When system_server tries to parse the APK file of the embedded app from the active install session, it will crash due to an uncaught error (i.e., java.lang.OutOfMemoryError) or an uncaught exception (i.e., std::bad_alloc) because of memory constraints. The Samsung Android device will encounter a soft reboot due to a system_server crash, and this action will keep repeating since parsing the APKs in the /data/app directory as performed by the system_server process is part of the normal boot process. The Samsung ID is SVE-2016-6917. | HIGH | Jan 10, 2017 |
CVE-2017-5216 | Stack-based buffer overflow vulnerability in Netop Remote Control versions 11.53, 12.21 and prior. The affected module in the Guest client is the Import to Phonebook option. When a specially designed malicious file containing special characters is loaded, the overflow occurs. 12.51 is the fixed version. The Support case ref is 00109744. | MEDIUM | Jan 10, 2017 |
CVE-2017-5215 | The Codextrous B2J Contact (aka b2j_contact) extension before 2.1.13 for Joomla! allows a rename attack that bypasses a safe file extension protection mechanism, leading to remote code execution. | HIGH | May 17, 2017 |
CVE-2017-5214 | The Codextrous B2J Contact (aka b2j_contact) extension before 2.1.13 for Joomla! allows prediction of a uniqid value based on knowledge of a time value. This makes it easier to read arbitrary uploaded files. | MEDIUM | May 17, 2017 |
CVE-2017-5213 | Open-Xchange GmbH OX App Suite 7.8.3 and earlier is affected by: Cross Site Scripting (XSS). | MEDIUM | May 23, 2019 |
CVE-2017-5212 | Open-Xchange GmbH OX App Suite 7.8.3 is affected by: Incorrect Access Control. | HIGH | May 23, 2019 |
CVE-2017-5211 | Open-Xchange GmbH OX App Suite 7.8.3 and earlier is affected by: Content Spoofing. | MEDIUM | May 23, 2019 |
CVE-2017-5210 | Open-Xchange GmbH OX App Suite 7.8.3 and earlier is affected by: Information Exposure. | MEDIUM | May 23, 2019 |
CVE-2017-5209 | The base64decode function in base64.c in libimobiledevice libplist through 1.12 allows attackers to obtain sensitive information from process memory or cause a denial of service (buffer over-read) via split encoded Apple Property List data. | MEDIUM | Jan 13, 2017 |
CVE-2017-5208 | Integer overflow in the wrestool program in icoutils before 0.31.1 allows remote attackers to cause a denial of service (memory corruption) via a crafted executable, which triggers a denial of service (application crash) or the possibility of execution of arbitrary code. | MEDIUM | Aug 22, 2017 |
CVE-2017-5207 | Firejail before 0.9.44.4, when running a bandwidth command, allows local users to gain root privileges via the --shell argument. | HIGH | Mar 27, 2017 |
CVE-2017-5206 | Firejail before 0.9.44.4, when running on a Linux kernel before 4.8, allows context-dependent attackers to bypass a seccomp-based sandbox protection mechanism via the --allow-debuggers argument. | MEDIUM | Mar 27, 2017 |
CVE-2017-5205 | The ISAKMP parser in tcpdump before 4.9.0 has a buffer overflow in print-isakmp.c:ikev2_e_print(). | HIGH | Feb 1, 2017 |
CVE-2017-5204 | The IPv6 parser in tcpdump before 4.9.0 has a buffer overflow in print-ip6.c:ip6_print(). | HIGH | Feb 1, 2017 |
CVE-2017-5203 | The BOOTP parser in tcpdump before 4.9.0 has a buffer overflow in print-bootp.c:bootp_print(). | HIGH | Feb 1, 2017 |
CVE-2017-5202 | The ISO CLNS parser in tcpdump before 4.9.0 has a buffer overflow in print-isoclns.c:clnp_print(). | HIGH | Feb 1, 2017 |
CVE-2017-5201 | NetApp Clustered Data ONTAP before 8.3.2P8 and 9.0 before P2 allow remote authenticated users to obtain sensitive cluster and tenant information via unspecified vectors, a different vulnerability than CVE-2016-3064. | LOW | Nov 9, 2017 |
CVE-2017-5200 | Salt-api in SaltStack Salt before 2015.8.13, 2016.3.x before 2016.3.5, and 2016.11.x before 2016.11.2 allows arbitrary command execution on a salt-master via Salt's ssh_client. | High | Oct 6, 2017 |
CVE-2017-5199 | The editbanner feature in SolarWinds LEM (aka SIEM) through 6.3.1 allows remote authenticated users to execute arbitrary code by editing /usr/local/contego/scripts/mgrconfig.pl. | MEDIUM | Mar 27, 2017 |
CVE-2017-5198 | SolarWinds LEM (aka SIEM) before 6.3.1 has an incorrect sudo configuration, which allows local users to obtain root access by editing /usr/local/contego/scripts/hostname.sh. | HIGH | Mar 27, 2017 |
CVE-2017-5197 | There is XSS in SilverStripe CMS before 3.4.4 and 3.5.x before 3.5.2. The attack vector is a page name. An example payload is a crafted JavaScript event handler within a malformed SVG element. | MEDIUM | Mar 7, 2017 |
CVE-2017-5196 | Irssi 0.8.18 before 0.8.21 allows remote attackers to cause a denial of service (out-of-bounds read and crash) via vectors involving strings that are not UTF8. | MEDIUM | Mar 7, 2017 |
CVE-2017-5195 | Irssi 0.8.17 before 0.8.21 allows remote attackers to cause a denial of service (out-of-bounds read and crash) via a crafted ANSI x8 color code. | MEDIUM | Mar 7, 2017 |
CVE-2017-5194 | Use-after-free vulnerability in Irssi before 0.8.21 allows remote attackers to cause a denial of service (crash) via an invalid nick message. | MEDIUM | Mar 6, 2017 |
CVE-2017-5193 | The nickcmp function in Irssi before 0.8.21 allows remote attackers to cause a denial of service (NULL pointer dereference and crash) via a message without a nick. | MEDIUM | Mar 7, 2017 |
CVE-2017-5192 | When using the local_batch client from salt-api in SaltStack Salt before 2015.8.13, 2016.3.x before 2016.3.5, and 2016.11.x before 2016.11.2, external authentication is not respected, enabling all authentication to be bypassed. | Medium | Oct 6, 2017 |
CVE-2017-5191 | An XSS vulnerability on the /NAGErrors URI in NetIQ Access Manager 4.2 and 4.3 exists because Access Gateway Error pages do not validate the HTTP Referer header. | MEDIUM | Apr 24, 2017 |
CVE-2017-5190 | NetIQ Access Manager 4.2 before SP3 HF1 and 4.3 before SP1 HF1, when configured as a SAML 2.0 Identity Server with Virtual Attributes, has a concurrency issue causing information leakage, related to a stale profile. | LOW | Apr 20, 2017 |
CVE-2017-5189 | NetIQ iManager before 3.0.3 delivered a SSL private key in a Java application (JAR file) for authentication to Sentinel, allowing attackers to extract and establish their own connections to the Sentinel appliance. | MEDIUM | Mar 2, 2018 |
CVE-2017-5188 | The bs_worker code in open build service before 20170320 followed relative symlinks, allowing reading of files outside of the package source directory during build, allowing leakage of private information. | MEDIUM | Mar 1, 2018 |
CVE-2017-5187 | A Cross-Site Request Forgery (CWE-352) vulnerability in Directory Server (aka Enterprise Server Administration web UI) in Micro Focus Enterprise Developer and Enterprise Server 2.3 and earlier, 2.3 Update 1 before Hotfix 8, and 2.3 Update 2 before Hotfix 9 allows remote unauthenticated attackers to view and alter (CWE-275) configuration information and inject OS commands (CWE-78) via forged requests. | MEDIUM | Aug 21, 2017 |
CVE-2017-5186 | Novell iManager 2.7 before SP7 Patch 9, NetIQ iManager 3.x before 3.0.2.1, Novell eDirectory 8.8.x before 8.8 SP8 Patch 9 Hotfix 2, and NetIQ eDirectory 9.x before 9.0.2 Hotfix 2 (9.0.2.2) use the deprecated MD5 hashing algorithm in a communications certificate. | MEDIUM | May 11, 2017 |
CVE-2017-5185 | A vulnerability was discovered in NetIQ Sentinel Server 8.0 before 8.0.1 that may allow remote denial of service. | MEDIUM | Apr 4, 2017 |
CVE-2017-5184 | A vulnerability was discovered in NetIQ Sentinel Server 8.0 before 8.0.1 that may allow leakage of information (account enumeration). | MEDIUM | Apr 4, 2017 |
CVE-2017-5183 | NetIQ Access Manager 4.2.2 and 4.3.x before 4.3.1+, when configured as an Identity Server, has XSS in the AssertionConsumerServiceURL field of a signed AuthnRequest in a samlp:AuthnRequest document. | MEDIUM | Apr 20, 2017 |
CVE-2017-5182 | Remote Manager in Open Enterprise Server (OES) allows unauthenticated remote attackers to read any arbitrary file, via a specially crafted URL, that allows complete directory traversal and total information disclosure. This vulnerability is present on all versions of OES for linux, it applies to OES2015 SP1 before Maintenance Update 11080, OES2015 before Maintenance Update 11079, OES11 SP3 before Maintenance Update 11078, OES11 SP2 before Maintenance Update 11077). | HIGH | Jan 26, 2017 |
CVE-2017-5181 | Rejected reason: DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: CVE-2017-7692. Reason: This candidate is a reservation duplicate of CVE-2017-7692. Notes: All CVE users should reference CVE-2017-7692 instead of this candidate. All references and descriptions in this candidate have been removed to prevent accidental usage | -- | Nov 7, 2023 |
CVE-2017-5180 | Firejail before 0.9.44.4 and 0.9.38.x LTS before 0.9.38.8 LTS does not consider the .Xauthority case during its attempt to prevent accessing user files with an euid of zero, which allows local users to conduct sandbox-escape attacks via vectors involving a symlink and the --private option. | MEDIUM | Feb 10, 2017 |
CVE-2017-5179 | Cross-site scripting (XSS) vulnerability in Tenable Nessus before 6.9.3 allows remote authenticated users to inject arbitrary web script or HTML via unspecified vectors. | LOW | Jan 10, 2017 |
CVE-2017-5178 | An issue was discovered in Schneider Electric Tableau Server/Desktop Versions 7.0 to 10.1.3 in Wonderware Intelligence Versions 2014R3 and prior. These versions contain a system account that is installed by default. The default system account is difficult to configure with non-default credentials after installation, and changing the default credentials in the embedded Tableau Server is not documented. If Tableau Server is used with Windows integrated security (Active Directory), the software is not vulnerable. However, when Tableau Server is used with local authentication mode, the software is vulnerable. The default system account could be used to gain unauthorized access. | HIGH | Mar 10, 2017 |
CVE-2017-5177 | A Stack Buffer Overflow issue was discovered in VIPA Controls WinPLC7 5.0.45.5921 and prior. A stack-based buffer overflow vulnerability has been identified, where an attacker with a specially crafted packet could overflow the fixed length buffer. This could allow remote code execution. | MEDIUM | May 19, 2017 |
CVE-2017-5176 | A DLL Hijack issue was discovered in Rockwell Automation Connected Components Workbench (CCW). The following versions are affected: Connected Components Workbench - Developer Edition, v9.01.00 and earlier: 9328-CCWDEVENE, 9328-CCWDEVZHE, 9328-CCWDEVFRE, 9328-CCWDEVITE, 9328-CCWDEVDEE, 9328-CCWDEVESE, and 9328-CCWDEVPTE; and Connected Components Workbench - Free Standard Edition (All Supported Languages), v9.01.00 and earlier. Certain DLLs included with versions of CCW software can be potentially hijacked to allow an attacker to gain rights to a victim's affected personal computer. Such access rights can be at the same or potentially higher level of privileges as the compromised user account, including and up to computer administrator privileges. | MEDIUM | May 19, 2017 |
CVE-2017-5175 | Advantech WebAccess 8.1 and earlier contains a DLL hijacking vulnerability which may allow an attacker to run a malicious DLL file within the search path resulting in execution of arbitrary code. | MEDIUM | May 9, 2018 |
CVE-2017-5174 | An Authentication Bypass issue was discovered in Geutebruck IP Camera G-Cam/EFD-2250 Version 1.11.0.12. An authentication bypass vulnerability has been identified. The existing file system architecture could allow attackers to bypass the access control that may allow remote code execution. | HIGH | May 19, 2017 |
CVE-2017-5173 | An Improper Neutralization of Special Elements (in an OS command) issue was discovered in Geutebruck IP Camera G-Cam/EFD-2250 Version 1.11.0.12. An improper neutralization of special elements vulnerability has been identified. If special elements are not properly neutralized, an attacker can call multiple parameters that can allow access to the root level operating system which could allow remote code execution. | HIGH | May 19, 2017 |
CVE-2017-5170 | An Uncontrolled Search Path Element issue was discovered in Moxa SoftNVR-IA Live Viewer, Version 3.30.3122 and prior versions. An uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. The attacker needs to have administrative access to the default install location in order to plant the insecure DLL. Once loaded by the application, the DLL could run malicious code at the privilege level of the application. | MEDIUM | Jan 19, 2018 |
CVE-2017-5169 | An issue was discovered in Hanwha Techwin Smart Security Manager Versions 1.5 and prior. Multiple Cross Site Request Forgery vulnerabilities have been identified. The flaws exist within the Redis and Apache Felix Gogo servers that are installed as part of this product. By issuing specific HTTP Post requests, an attacker can gain system level access to a remote shell session. Smart Security Manager Versions 1.5 and prior are affected by these vulnerabilities. These vulnerabilities can allow for remote code execution. | MEDIUM | Feb 24, 2017 |
CVE-2017-5168 | An issue was discovered in Hanwha Techwin Smart Security Manager Versions 1.5 and prior. Multiple Path Traversal vulnerabilities have been identified. The flaws exist within the ActiveMQ Broker service that is installed as part of the product. By issuing specific HTTP requests, if a user visits a malicious page, an attacker can gain access to arbitrary files on the server. Smart Security Manager Versions 1.4 and prior to 1.31 are affected by these vulnerabilities. These vulnerabilities can allow for remote code execution. | MEDIUM | Feb 24, 2017 |
CVE-2017-5167 | An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own passwords. | HIGH | Feb 16, 2017 |
CVE-2017-5166 | An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. An INFORMATION EXPOSURE flaw can be used to gain privileged access to the device. | MEDIUM | Feb 16, 2017 |