Wind River Support Network

HomeDefectsLIN6-7370
Fixed

LIN6-7370 : ANATOP-THERMAL value is abnormal and critical temperature setting failed to make system reboot

Created: May 8, 2014    Updated: Dec 3, 2018
Resolved Date: May 11, 2014
Found In Version: 6.0
Fix Version: 6.0.0.6
Severity: Severe
Applicable for: Wind River Linux 6
Component/s: BSP - Async

Description

root@localhost:~# cd /sys/class/thermal/thermal_zone0
root@localhost:/sys/class/thermal/thermal_zone0# cat temp
45646
root@localhost:/sys/class/thermal/thermal_zone0# echo 5000000 > trip_point_0_temp

System doesn't reboot as expected with such critical temperature setting

Testing board is fsl-imx6 sabresd

Steps to Reproduce

1. Configure
/lpg-build/cdc/fast_prod/wrlinux6006/dvd_install/lx03_13fa/wrlinux-6/wrlinux/configure --enable-board=fsl-imx6 --enable-kernel=preempt-rt --enable-rootfs=glibc_std --with-layer=/wr-testing/kts-test,/wr-testing/bts --with-template=feature/kts-basic,feature/kts-extended,feature/kts-rt --enable-jobs=10 --enable-parallel-pkgbuilds=10 --with-rcpl-version=0006

2. make fs