CVE-2020-8485 | Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash. | MEDIUM | Apr 29, 2020 |
CVE-2020-8484 | Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash. | MEDIUM | Apr 29, 2020 |
CVE-2020-8482 | Insecure storage of sensitive information in ABB Device Library Wizard versions 6.0.X, 6.0.3.1 and 6.0.3.2 allows unauthenticated low privilege user to read file that contains confidential data | LOW | May 30, 2020 |
CVE-2020-8481 | For ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, confidential data is written in an unprotected file. An attacker who successfully exploited this vulnerability could take full control of the computer. | HIGH | Apr 29, 2020 |
CVE-2020-8479 | For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5. an XML External Entity Injection vulnerability exists that allows an attacker to read or call arbitrary files from the license server and/or from the network and also block the license handling. | HIGH | Apr 29, 2020 |
CVE-2020-8478 | Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder. | LOW | Apr 29, 2020 |
CVE-2020-8477 | The installations for ABB System 800xA Information Manager versions 5.1, 6.0 to 6.0.3.2 and 6.1 wrongly contain an auxiliary component. An attacker is able to use this for an XSS-like attack to an authenticated local user, which might lead to execution of arbitrary code. | MEDIUM | Apr 22, 2020 |
CVE-2020-8476 | For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to alter licenses assigned to the system nodes by sending specially crafted messages to the CLS web service. | MEDIUM | Apr 29, 2020 |
CVE-2020-8475 | For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to block license handling by sending specially crafted messages to the CLS web service. | LOW | Apr 29, 2020 |
CVE-2020-8474 | Weak Registry permissions in ABB System 800xA Base allow low privileged users to read and modify registry settings related to control system functionality, allowing an authenticated attacker to cause system functions to stop or malfunction. | MEDIUM | Apr 22, 2020 |
CVE-2020-8473 | Insufficient folder permissions used by system functions in ABB System 800xA Base (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploit the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications. | MEDIUM | Apr 29, 2020 |
CVE-2020-8472 | Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and earlier) and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploited the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications. | MEDIUM | Apr 29, 2020 |
CVE-2020-8471 | For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code. | MEDIUM | Apr 29, 2020 |
CVE-2020-8470 | Trend Micro Apex One (2019), OfficeScan XG and Worry-Free Business Security (9.0, 9.5, 10.0) server contains a vulnerable service DLL file that could allow an attacker to delete any file on the server with SYSTEM level privileges. Authentication is not required to exploit this vulnerability. | HIGH | Mar 19, 2020 |
CVE-2020-8469 | Trend Micro Password Manager for Windows version 5.0 is affected by a DLL hijacking vulnerability would could potentially allow an attacker privleged escalation. | MEDIUM | Mar 12, 2020 |
CVE-2020-8468 | Trend Micro Apex One (2019), OfficeScan XG and Worry-Free Business Security (9.0, 9.5, 10.0) agents are affected by a content validation escape vulnerability which could allow an attacker to manipulate certain agent client components. An attempted attack requires user authentication. | MEDIUM | Mar 19, 2020 |
CVE-2020-8467 | A migration tool component of Trend Micro Apex One (2019) and OfficeScan XG contains a vulnerability which could allow remote attackers to execute arbitrary code on affected installations (RCE). An attempted attack requires user authentication. | MEDIUM | Mar 18, 2020 |
CVE-2020-8466 | A command injection vulnerability in Trend Micro InterScan Web Security Virtual Appliance 6.5 SP2, with the improved password hashing method enabled, could allow an unauthenticated attacker to execute certain commands by providing a manipulated password. | HIGH | Dec 17, 2020 |
CVE-2020-8465 | A vulnerability in Trend Micro InterScan Web Security Virtual Appliance 6.5 SP2 could allow an attacker to manipulate system updates using a combination of CSRF bypass (CVE-2020-8461) and authentication bypass (CVE-2020-8464) to execute code as user root. | HIGH | Dec 17, 2020 |
CVE-2020-8464 | A vulnerability in Trend Micro InterScan Web Security Virtual Appliance 6.5 SP2 could allow an attacker to send requests that appear to come from the localhost which could expose the product\'s admin interface to users who would not normally have access. | MEDIUM | Dec 17, 2020 |
CVE-2020-8463 | A vulnerability in Trend Micro InterScan Web Security Virtual Appliance 6.5 SP2 could allow an attacker to bypass a global authorization check for anonymous users by manipulating request paths. | MEDIUM | Dec 17, 2020 |
CVE-2020-8462 | A cross-site scripting (XSS) vulnerability in Trend Micro InterScan Web Security Virtual Appliance 6.5 SP2 could allow an attacker to tamper with the web interface of the product. | LOW | Dec 17, 2020 |
CVE-2020-8461 | A CSRF protection bypass vulnerability in Trend Micro InterScan Web Security Virtual Appliance 6.5 SP2 could allow an attacker to get a victim\'s browser to send a specifically encoded request without requiring a valid CSRF token. | MEDIUM | Dec 17, 2020 |
CVE-2020-8450 | An issue was discovered in Squid before 4.10. Due to incorrect buffer management, a remote client can cause a buffer overflow in a Squid instance acting as a reverse proxy. | HIGH | Feb 6, 2020 |
CVE-2020-8449 | An issue was discovered in Squid before 4.10. Due to incorrect input validation, it can interpret crafted HTTP requests in unexpected ways to access server resources prohibited by earlier security filters. | MEDIUM | Feb 6, 2020 |
CVE-2020-8448 | In OSSEC-HIDS 2.7 through 3.5.0, the server component responsible for log analysis (ossec-analysisd) is vulnerable to a denial of service (NULL pointer dereference) via crafted messages written directly to the analysisd UNIX domain socket by a local user. | LOW | Feb 1, 2020 |
CVE-2020-8447 | In OSSEC-HIDS 2.7 through 3.5.0, the server component responsible for log analysis (ossec-analysisd) is vulnerable to a use-after-free during processing of syscheck formatted msgs (received from authenticated remote agents and delivered to the analysisd processing queue by ossec-remoted). | HIGH | Feb 3, 2020 |
CVE-2020-8446 | In OSSEC-HIDS 2.7 through 3.5.0, the server component responsible for log analysis (ossec-analysisd) is vulnerable to path traversal (with write access) via crafted syscheck messages written directly to the analysisd UNIX domain socket by a local user. | LOW | Feb 1, 2020 |
CVE-2020-8445 | In OSSEC-HIDS 2.7 through 3.5.0, the OS_CleanMSG function in ossec-analysisd doesn\'t remove or encode terminal control characters or newlines from processed log messages. In many cases, those characters are later logged. Because newlines (\\n) are permitted in messages processed by ossec-analysisd, it may be possible to inject nested events into the ossec log. Use of terminal control characters may allow obfuscating events or executing commands when viewed through vulnerable terminal emulators. This may be an unauthenticated remote attack for certain types and origins of logged data. | HIGH | Feb 5, 2020 |
CVE-2020-8444 | In OSSEC-HIDS 2.7 through 3.5.0, the server component responsible for log analysis (ossec-analysisd) is vulnerable to a use-after-free during processing of ossec-alert formatted msgs (received from authenticated remote agents and delivered to the analysisd processing queue by ossec-remoted). | HIGH | Feb 3, 2020 |
CVE-2020-8443 | In OSSEC-HIDS 2.7 through 3.5.0, the server component responsible for log analysis (ossec-analysisd) is vulnerable to an off-by-one heap-based buffer overflow during the cleaning of crafted syslog msgs (received from authenticated remote agents and delivered to the analysisd processing queue by ossec-remoted). | HIGH | Feb 3, 2020 |
CVE-2020-8442 | In OSSEC-HIDS 2.7 through 3.5.0, the server component responsible for log analysis (ossec-analysisd) is vulnerable to a heap-based buffer overflow in the rootcheck decoder component via an authenticated client. | MEDIUM | Feb 1, 2020 |
CVE-2020-8441 | JYaml through 1.3 allows remote code execution during deserialization of a malicious payload through the load() function. NOTE: this is a discontinued product. | HIGH | Feb 26, 2020 |
CVE-2020-8440 | controllers/page_apply.php in Simplejobscript.com SJS through 1.66 is prone to unauthenticated Remote Code Execution by uploading a PHP script as a resume. | HIGH | Feb 5, 2020 |
CVE-2020-8439 | Monstra CMS through 3.0.4 allows remote authenticated users to take over arbitrary user accounts via a modified login parameter to an edit URI, as demonstrated by login=victim to the users/21/edit URI. | MEDIUM | Mar 9, 2020 |
CVE-2020-8438 | Ruckus ZoneFlex R500 104.0.0.0.1347 devices allow an authenticated attacker to execute arbitrary OS commands via the hidden /forms/nslookupHandler form, as demonstrated by the nslookuptarget=|cat${IFS} substring. | HIGH | Jan 31, 2020 |
CVE-2020-8437 | The bencoding parser in BitTorrent uTorrent through 3.5.5 (build 45505) misparses nested bencoded dictionaries, which allows a remote attacker to cause a denial of service. | MEDIUM | Mar 5, 2020 |
CVE-2020-8436 | XSS was discovered in the RegistrationMagic plugin 4.6.0.0 for WordPress via the rm_form_id, rm_tr, or form_name parameter. | MEDIUM | Mar 12, 2020 |
CVE-2020-8435 | An issue was discovered in the RegistrationMagic plugin 4.6.0.0 for WordPress. There is SQL injection via the rm_analytics_show_form rm_form_id parameter. | MEDIUM | Mar 12, 2020 |
CVE-2020-8434 | Jenzabar JICS (aka Internet Campus Solution) before 9.0.1 Patch 3, 9.1 before 9.1.2 Patch 2, and 9.2 before 9.2.2 Patch 8 has session cookies that are a deterministic function of the username. There is a hard-coded password to supply a PBKDF feeding into AES to encrypt a username and base64 encode it to a client-side cookie for persistent session authentication. By knowing the key and algorithm, an attacker can select any username, encrypt it, base64 encode it, and save it in their browser with the correct JICSLoginCookie cookie format to impersonate any real user in the JICS database without the need for authenticating (or verifying with MFA if implemented). | MEDIUM | May 19, 2020 |
CVE-2020-8432 | In Das U-Boot through 2020.01, a double free has been found in the cmd/gpt.c do_rename_gpt_parts() function. Double freeing may result in a write-what-where condition, allowing an attacker to execute arbitrary code. NOTE: this vulnerablity was introduced when attempting to fix a memory leak identified by static analysis. | HIGH | Feb 5, 2020 |
CVE-2020-8430 | Stormshield Network Security 310 3.7.10 devices have an auth/lang.html?rurl= Open Redirect vulnerability on the captive portal. For example, the attacker can use rurl=//example.com instead of rurl=https://example.com in the query string. | MEDIUM | Apr 13, 2020 |
CVE-2020-8429 | The Admin web application in Kinetica 7.0.9.2.20191118151947 does not properly sanitise the input for the function getLogs. This lack of sanitisation could be exploited to allow an authenticated attacker to run remote code on the underlying operating system. The logFile parameter in the getLogs function was used as a variable in a command to read log files; however, due to poor input sanitisation, it was possible to bypass a replacement and break out of the command. | HIGH | Feb 11, 2020 |
CVE-2020-8428 | fs/namei.c in the Linux kernel before 5.5 has a may_create_in_sticky use-after-free, which allows local users to cause a denial of service (OOPS) or possibly obtain sensitive information from kernel memory, aka CID-d0cb50185ae9. One attack vector may be an open system call for a UNIX domain socket, if the socket is being moved to a new parent directory and its old parent directory is being removed. | LOW | Feb 2, 2020 |
CVE-2020-8427 | In Unitrends Backup before 10.4.1, an HTTP request parameter was not properly sanitized, allowing for SQL injection that resulted in an authentication bypass. | HIGH | Feb 28, 2020 |
CVE-2020-8426 | The Elementor plugin before 2.8.5 for WordPress suffers from a reflected XSS vulnerability on the elementor-system-info page. These can be exploited by targeting an authenticated user. | LOW | Jan 31, 2020 |
CVE-2020-8425 | Cups Easy (Purchase & Inventory) 1.0 is vulnerable to CSRF that leads to admin account deletion via userdelete.php. | MEDIUM | Feb 7, 2020 |
CVE-2020-8424 | Cups Easy (Purchase & Inventory) 1.0 is vulnerable to CSRF that leads to admin account takeover via passwordmychange.php. | MEDIUM | Feb 6, 2020 |
CVE-2020-8423 | A buffer overflow in the httpd daemon on TP-Link TL-WR841N V10 (firmware version 3.16.9) devices allows an authenticated remote attacker to execute arbitrary code via a GET request to the page for the configuration of the Wi-Fi network. | HIGH | Apr 2, 2020 |
CVE-2020-8422 | An authorization issue was discovered in the Credential Manager feature in Zoho ManageEngine Remote Access Plus before 10.0.450. A user with the Guest role can extract the collection of all defined credentials of remote machines: the credential name, credential type, user name, domain/workgroup name, and description (but not the password). | MEDIUM | Feb 4, 2020 |