CVE-2018-17927 In Delta Industrial Automation TPEditor, TPEditor Versions 1.90 and prior, multiple out-of-bounds write vulnerabilities may be exploited by processing specially crafted project files lacking user input validation, which may cause the system to write outside the intended buffer area and may allow remote code execution. MEDIUM Oct 11, 2018
CVE-2018-17926 The product M2M ETHERNET (FW Versions 2.22 and prior, ETH-FW Versions 1.01 and prior) is vulnerable in that an attacker can upload a malicious language file by bypassing the user authentication mechanism. LOW Feb 1, 2019
CVE-2018-17925 Multiple instances of this vulnerability (Unsafe ActiveX Control Marked Safe For Scripting) have been identified in the third-party ActiveX object provided to GE iFIX versions 2.0 - 5.8 by Gigasoft. Only the independent use of the Gigasoft charting package outside the iFIX product may expose users to the reported vulnerability. The reported method shown to impact Internet Explorer is not exposed in the iFIX product, nor is the core functionality of the iFIX product known to be impacted. MEDIUM Oct 10, 2018
CVE-2018-17924 Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules An unauthenticated, remote threat actor could send a CIP connection request to an affected device, and upon successful connection, send a new IP configuration to the affected device even if the controller in the system is set to Hard RUN mode. When the affected device accepts this new IP configuration, a loss of communication occurs between the device and the rest of the system as the system traffic is still attempting to communicate with the device via the overwritten IP address. HIGH Dec 8, 2018
CVE-2018-17923 SAGA1-L8B with any firmware versions prior to A0.10 are vulnerable to an attack that an attacker with physical access to the product may able to reprogram it. MEDIUM Oct 26, 2018
CVE-2018-17922 Circontrol CirCarLife all versions prior to 4.3.1, the PAP credentials of the device are stored in clear text in a log file that is accessible without authentication. MEDIUM Nov 6, 2018
CVE-2018-17921 SAGA1-L8B with any firmware versions prior to A0.10 are vulnerable to an attack that may allow an attacker to force-pair the device without human interaction. MEDIUM Oct 26, 2018
CVE-2018-17919 All versions of Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server may allow an attacker to use an undocumented user account default with its default password to login to XMeye and access/view video streams. MEDIUM Oct 10, 2018
CVE-2018-17918 Circontrol CirCarLife all versions prior to 4.3.1, authentication to the device can be bypassed by entering the URL of a specific page. HIGH Nov 6, 2018
CVE-2018-17917 All versions of Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server may allow an attacker to use MAC addresses to enumerate potential Cloud IDs. Using this ID, the attacker can discover and connect to valid devices using one of the supported apps. MEDIUM Oct 10, 2018
CVE-2018-17916 InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. A remote attacker could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability during tag, alarm, or event related actions such as read and write, with potential for code to be executed. If InduSoft Web Studio remote communication security was not enabled, or a password was left blank, a remote user could send a carefully crafted packet to invoke an arbitrary process, with potential for code to be executed. The code would be executed under the privileges of the InduSoft Web Studio or InTouch Edge HMI runtime and could lead to a compromise of the InduSoft Web Studio or InTouch Edge HMI server machine. HIGH Nov 3, 2018
CVE-2018-17915 All versions of Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server do not encrypt all device communication. This includes the XMeye service and firmware update communication. This could allow an attacker to eavesdrop on video feeds, steal XMeye login credentials, or impersonate the update server with malicious update code. MEDIUM Oct 10, 2018
CVE-2018-17914 InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. This vulnerability could allow an unauthenticated user to remotely execute code with the same privileges as that of the InduSoft Web Studio or InTouch Edge HMI (formerly InTouch Machine Edition) runtime. HIGH Nov 3, 2018
CVE-2018-17913 A type confusion vulnerability exists when processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior, which may allow an attacker to execute code in the context of the application. MEDIUM Nov 6, 2018
CVE-2018-17912 An XXE vulnerability exists in CASE Suite Versions 3.10 and prior when processing parameter entities, which may allow remote file disclosure. MEDIUM Nov 5, 2018
CVE-2018-17911 LAquis SCADA Versions 4.1.0.3870 and prior has several stack-based buffer overflow vulnerabilities, which may allow remote code execution. MEDIUM Oct 16, 2018
CVE-2018-17910 WebAccess Versions 8.3.2 and prior. The application fails to properly validate the length of user-supplied data, causing a buffer overflow condition that allows for arbitrary remote code execution. HIGH Oct 29, 2018
CVE-2018-17909 When processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior, the application fails to check if it is referencing freed memory, which may allow an attacker to execute code under the context of the application. MEDIUM Nov 6, 2018
CVE-2018-17908 WebAccess Versions 8.3.2 and prior. During installation, the application installer disables user access control and does not re-enable it after the installation is complete. This could allow an attacker to run elevated arbitrary code. HIGH Oct 29, 2018
CVE-2018-17907 When processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior and tampering with the value of an offset, an attacker can force the application to read a value outside of an array. MEDIUM Nov 6, 2018
CVE-2018-17906 Philips iSite and IntelliSpace PACS, iSite PACS, all versions, and IntelliSpace PACS, all versions. Default credentials and no authentication within third party software may allow an attacker to compromise a component of the system. LOW Nov 20, 2018
CVE-2018-17905 When processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior and tampering with a specific byte, memory corruption may occur within a specific object. MEDIUM Nov 6, 2018
CVE-2018-17904 Reliance 4 SCADA/HMI, Version 4.7.3 Update 3 and prior. This vulnerability could allow an unauthorized attacker to inject arbitrary code. MEDIUM Oct 26, 2018
CVE-2018-17903 SAGA1-L8B with any firmware versions prior to A0.10 are vulnerable to a replay attack and command forgery. MEDIUM Oct 26, 2018
CVE-2018-17902 Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The application utilizes multiple methods of session management which could result in a denial of service to the remote management functions. MEDIUM Oct 12, 2018
CVE-2018-17901 LAquis SCADA Versions 4.1.0.3870 and prior, when processing project files the application fails to sanitize user input prior to performing write operations on a stack object, which may allow an attacker to execute code under the current process. MEDIUM Oct 16, 2018
CVE-2018-17900 Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The web application improperly protects credentials which could allow an attacker to obtain credentials for remote access to controllers. MEDIUM Oct 12, 2018
CVE-2018-17899 LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution. MEDIUM Oct 16, 2018
CVE-2018-17898 Yokogawa STARDOM Controllers FCJ,FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The controller application fails to prevent memory exhaustion by unauthorized requests. This could allow an attacker to cause the controller to become unstable. HIGH Oct 12, 2018
CVE-2018-17897 LAquis SCADA Versions 4.1.0.3870 and prior has several integer overflow to buffer overflow vulnerabilities, which may allow remote code execution. HIGH Oct 16, 2018
CVE-2018-17896 Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The affected controllers utilize hard-coded credentials which may allow an attacker gain unauthorized access to the maintenance functions and obtain or modify information. This attack can be executed only during maintenance work. HIGH Oct 12, 2018
CVE-2018-17895 LAquis SCADA Versions 4.1.0.3870 and prior has several out-of-bounds read vulnerabilities, which may allow remote code execution. HIGH Oct 16, 2018
CVE-2018-17894 NUUO CMS all versions 3.1 and prior, The application creates default accounts that have hard-coded passwords, which could allow an attacker to gain privileged access. HIGH Oct 12, 2018
CVE-2018-17893 LAquis SCADA Versions 4.1.0.3870 and prior has an untrusted pointer dereference vulnerability, which may allow remote code execution. HIGH Oct 16, 2018
CVE-2018-17892 NUUO CMS all versions 3.1 and prior, The application implements a method of user account control that causes standard account security features to not be utilized as intended, which could allow user account compromise and may allow for remote code execution. MEDIUM Oct 12, 2018
CVE-2018-17891 Carestream Vue RIS, RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5. When contacting a Carestream server where there is no Oracle TNS listener available, users will trigger an HTTP 500 error, leaking technical information an attacker could use to initiate a more elaborate attack. MEDIUM Oct 4, 2018
CVE-2018-17890 NUUO CMS all versions 3.1 and prior, The application uses insecure and outdated software components for functionality, which could allow arbitrary code execution. HIGH Oct 12, 2018
CVE-2018-17889 In WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior when parsing project files, the XMLParser that ships with Wecon PIStudio is vulnerable to a XML external entity injection attack, which may allow sensitive information disclosure. MEDIUM Oct 8, 2018
CVE-2018-17888 NUUO CMS all versions 3.1 and prior, The application uses a session identification mechanism that could allow attackers to obtain the active session ID, which could allow arbitrary remote code execution. HIGH Oct 12, 2018
CVE-2018-17886 An issue was discovered in JEESNS 1.3. The XSS filter in com.lxinet.jeesns.core.utils.XssHttpServletRequestWrapper.java could be bypassed, as demonstrated by a <svg/onLoad=confirm substring. NOTE: this vulnerability exists because of an incomplete fix for CVE-2018-12429. LOW Oct 2, 2018
CVE-2018-17884 XSS exists in admin/gb-dashboard-widget.php in the Gwolle Guestbook (gwolle-gb) plugin before 2.5.4 for WordPress via the PATH_INFO to wp-admin/index.php MEDIUM Oct 2, 2018
CVE-2018-17883 An issue was discovered in Open Ticket Request System (OTRS) 6.0.x before 6.0.12. An attacker could send an e-mail message with a malicious link to an OTRS system or an agent. If a logged-in agent opens this link, it could cause the execution of JavaScript in the context of OTRS. -- Apr 17, 2023
CVE-2018-17882 An Integer overflow vulnerability exists in the batchTransfer function of a smart contract implementation for CryptoBotsBattle (CBTB), an Ethereum token. This vulnerability could be used by an attacker to create an arbitrary amount of tokens for any user. MEDIUM Mar 22, 2019
CVE-2018-17881 On D-Link DIR-823G 2018-09-19 devices, the GoAhead configuration allows /HNAP1 SetPasswdSettings commands without authentication to trigger an admin password change. MEDIUM Oct 3, 2018
CVE-2018-17880 On D-Link DIR-823G 2018-09-19 devices, the GoAhead configuration allows /HNAP1 RunReboot commands without authentication to trigger a reboot. HIGH Oct 3, 2018
CVE-2018-17879 An issue was discovered on certain ABUS TVIP cameras. The CGI scripts allow remote attackers to execute code via system() as root. There are several injection points in various scripts. -- Oct 26, 2023
CVE-2018-17878 Buffer Overflow vulnerability in certain ABUS TVIP cameras allows attackers to gain control of the program via crafted string sent to sprintf() function. -- Oct 26, 2023
CVE-2018-17877 A lottery smart contract implementation for Greedy 599, an Ethereum gambling game, generates a random value that is predictable via an external contract call. The developer used the extcodesize() function to prevent a malicious contract from being called, but the attacker can bypass it by writing the core code in the constructor of their exploit code. Therefore, it allows attackers to always win and get rewards. MEDIUM Oct 23, 2018
CVE-2018-17876 A Stored XSS vulnerability has been discovered in the v5.5.0 version of the Coaster CMS product. MEDIUM Oct 4, 2018
CVE-2018-17875 A remote code execution issue in the ping command on Poly Trio 8800 5.7.1.4145 devices allows remote authenticated users to execute commands via unspecified vectors. MEDIUM Dec 28, 2021
The 'Fixed Release' column is displayed if a single product version is selected from the filter. The fixed release is applicable in cases when the CVE has been addressed and fixed for that product version. Requires LTSS - customers must have active LTSS (Long Term Security Shield) Support to receive up-to-date information about vulnerabilities that may affect legacy software. Please contact your Wind River account team or see https://docs.windriver.com/bundle/Support_and_Maintenance_Supplemental_Terms_and_Conditions and https://support2.windriver.com/index.php?page=plc for more information.