ID | Description | Priority | Modified date |
---|---|---|---|
CVE-2018-17927 | In Delta Industrial Automation TPEditor, TPEditor Versions 1.90 and prior, multiple out-of-bounds write vulnerabilities may be exploited by processing specially crafted project files lacking user input validation, which may cause the system to write outside the intended buffer area and may allow remote code execution. | MEDIUM | Oct 11, 2018 |
CVE-2018-17926 | The product M2M ETHERNET (FW Versions 2.22 and prior, ETH-FW Versions 1.01 and prior) is vulnerable in that an attacker can upload a malicious language file by bypassing the user authentication mechanism. | LOW | Feb 1, 2019 |
CVE-2018-17925 | Multiple instances of this vulnerability (Unsafe ActiveX Control Marked Safe For Scripting) have been identified in the third-party ActiveX object provided to GE iFIX versions 2.0 - 5.8 by Gigasoft. Only the independent use of the Gigasoft charting package outside the iFIX product may expose users to the reported vulnerability. The reported method shown to impact Internet Explorer is not exposed in the iFIX product, nor is the core functionality of the iFIX product known to be impacted. | MEDIUM | Oct 10, 2018 |
CVE-2018-17924 | Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules An unauthenticated, remote threat actor could send a CIP connection request to an affected device, and upon successful connection, send a new IP configuration to the affected device even if the controller in the system is set to Hard RUN mode. When the affected device accepts this new IP configuration, a loss of communication occurs between the device and the rest of the system as the system traffic is still attempting to communicate with the device via the overwritten IP address. | HIGH | Dec 8, 2018 |
CVE-2018-17923 | SAGA1-L8B with any firmware versions prior to A0.10 are vulnerable to an attack that an attacker with physical access to the product may able to reprogram it. | MEDIUM | Oct 26, 2018 |
CVE-2018-17922 | Circontrol CirCarLife all versions prior to 4.3.1, the PAP credentials of the device are stored in clear text in a log file that is accessible without authentication. | MEDIUM | Nov 6, 2018 |
CVE-2018-17921 | SAGA1-L8B with any firmware versions prior to A0.10 are vulnerable to an attack that may allow an attacker to force-pair the device without human interaction. | MEDIUM | Oct 26, 2018 |
CVE-2018-17919 | All versions of Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server may allow an attacker to use an undocumented user account default with its default password to login to XMeye and access/view video streams. | MEDIUM | Oct 10, 2018 |
CVE-2018-17918 | Circontrol CirCarLife all versions prior to 4.3.1, authentication to the device can be bypassed by entering the URL of a specific page. | HIGH | Nov 6, 2018 |
CVE-2018-17917 | All versions of Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server may allow an attacker to use MAC addresses to enumerate potential Cloud IDs. Using this ID, the attacker can discover and connect to valid devices using one of the supported apps. | MEDIUM | Oct 10, 2018 |
CVE-2018-17916 | InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. A remote attacker could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability during tag, alarm, or event related actions such as read and write, with potential for code to be executed. If InduSoft Web Studio remote communication security was not enabled, or a password was left blank, a remote user could send a carefully crafted packet to invoke an arbitrary process, with potential for code to be executed. The code would be executed under the privileges of the InduSoft Web Studio or InTouch Edge HMI runtime and could lead to a compromise of the InduSoft Web Studio or InTouch Edge HMI server machine. | HIGH | Nov 3, 2018 |
CVE-2018-17915 | All versions of Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server do not encrypt all device communication. This includes the XMeye service and firmware update communication. This could allow an attacker to eavesdrop on video feeds, steal XMeye login credentials, or impersonate the update server with malicious update code. | MEDIUM | Oct 10, 2018 |
CVE-2018-17914 | InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. This vulnerability could allow an unauthenticated user to remotely execute code with the same privileges as that of the InduSoft Web Studio or InTouch Edge HMI (formerly InTouch Machine Edition) runtime. | HIGH | Nov 3, 2018 |
CVE-2018-17913 | A type confusion vulnerability exists when processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior, which may allow an attacker to execute code in the context of the application. | MEDIUM | Nov 6, 2018 |
CVE-2018-17912 | An XXE vulnerability exists in CASE Suite Versions 3.10 and prior when processing parameter entities, which may allow remote file disclosure. | MEDIUM | Nov 5, 2018 |
CVE-2018-17911 | LAquis SCADA Versions 4.1.0.3870 and prior has several stack-based buffer overflow vulnerabilities, which may allow remote code execution. | MEDIUM | Oct 16, 2018 |
CVE-2018-17910 | WebAccess Versions 8.3.2 and prior. The application fails to properly validate the length of user-supplied data, causing a buffer overflow condition that allows for arbitrary remote code execution. | HIGH | Oct 29, 2018 |
CVE-2018-17909 | When processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior, the application fails to check if it is referencing freed memory, which may allow an attacker to execute code under the context of the application. | MEDIUM | Nov 6, 2018 |
CVE-2018-17908 | WebAccess Versions 8.3.2 and prior. During installation, the application installer disables user access control and does not re-enable it after the installation is complete. This could allow an attacker to run elevated arbitrary code. | HIGH | Oct 29, 2018 |
CVE-2018-17907 | When processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior and tampering with the value of an offset, an attacker can force the application to read a value outside of an array. | MEDIUM | Nov 6, 2018 |
CVE-2018-17906 | Philips iSite and IntelliSpace PACS, iSite PACS, all versions, and IntelliSpace PACS, all versions. Default credentials and no authentication within third party software may allow an attacker to compromise a component of the system. | LOW | Nov 20, 2018 |
CVE-2018-17905 | When processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior and tampering with a specific byte, memory corruption may occur within a specific object. | MEDIUM | Nov 6, 2018 |
CVE-2018-17904 | Reliance 4 SCADA/HMI, Version 4.7.3 Update 3 and prior. This vulnerability could allow an unauthorized attacker to inject arbitrary code. | MEDIUM | Oct 26, 2018 |
CVE-2018-17903 | SAGA1-L8B with any firmware versions prior to A0.10 are vulnerable to a replay attack and command forgery. | MEDIUM | Oct 26, 2018 |
CVE-2018-17902 | Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The application utilizes multiple methods of session management which could result in a denial of service to the remote management functions. | MEDIUM | Oct 12, 2018 |
CVE-2018-17901 | LAquis SCADA Versions 4.1.0.3870 and prior, when processing project files the application fails to sanitize user input prior to performing write operations on a stack object, which may allow an attacker to execute code under the current process. | MEDIUM | Oct 16, 2018 |
CVE-2018-17900 | Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The web application improperly protects credentials which could allow an attacker to obtain credentials for remote access to controllers. | MEDIUM | Oct 12, 2018 |
CVE-2018-17899 | LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution. | MEDIUM | Oct 16, 2018 |
CVE-2018-17898 | Yokogawa STARDOM Controllers FCJ,FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The controller application fails to prevent memory exhaustion by unauthorized requests. This could allow an attacker to cause the controller to become unstable. | HIGH | Oct 12, 2018 |
CVE-2018-17897 | LAquis SCADA Versions 4.1.0.3870 and prior has several integer overflow to buffer overflow vulnerabilities, which may allow remote code execution. | HIGH | Oct 16, 2018 |
CVE-2018-17896 | Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The affected controllers utilize hard-coded credentials which may allow an attacker gain unauthorized access to the maintenance functions and obtain or modify information. This attack can be executed only during maintenance work. | HIGH | Oct 12, 2018 |
CVE-2018-17895 | LAquis SCADA Versions 4.1.0.3870 and prior has several out-of-bounds read vulnerabilities, which may allow remote code execution. | HIGH | Oct 16, 2018 |
CVE-2018-17894 | NUUO CMS all versions 3.1 and prior, The application creates default accounts that have hard-coded passwords, which could allow an attacker to gain privileged access. | HIGH | Oct 12, 2018 |
CVE-2018-17893 | LAquis SCADA Versions 4.1.0.3870 and prior has an untrusted pointer dereference vulnerability, which may allow remote code execution. | HIGH | Oct 16, 2018 |
CVE-2018-17892 | NUUO CMS all versions 3.1 and prior, The application implements a method of user account control that causes standard account security features to not be utilized as intended, which could allow user account compromise and may allow for remote code execution. | MEDIUM | Oct 12, 2018 |
CVE-2018-17891 | Carestream Vue RIS, RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5. When contacting a Carestream server where there is no Oracle TNS listener available, users will trigger an HTTP 500 error, leaking technical information an attacker could use to initiate a more elaborate attack. | MEDIUM | Oct 4, 2018 |
CVE-2018-17890 | NUUO CMS all versions 3.1 and prior, The application uses insecure and outdated software components for functionality, which could allow arbitrary code execution. | HIGH | Oct 12, 2018 |
CVE-2018-17889 | In WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior when parsing project files, the XMLParser that ships with Wecon PIStudio is vulnerable to a XML external entity injection attack, which may allow sensitive information disclosure. | MEDIUM | Oct 8, 2018 |
CVE-2018-17888 | NUUO CMS all versions 3.1 and prior, The application uses a session identification mechanism that could allow attackers to obtain the active session ID, which could allow arbitrary remote code execution. | HIGH | Oct 12, 2018 |
CVE-2018-17886 | An issue was discovered in JEESNS 1.3. The XSS filter in com.lxinet.jeesns.core.utils.XssHttpServletRequestWrapper.java could be bypassed, as demonstrated by a <svg/onLoad=confirm substring. NOTE: this vulnerability exists because of an incomplete fix for CVE-2018-12429. | LOW | Oct 2, 2018 |
CVE-2018-17884 | XSS exists in admin/gb-dashboard-widget.php in the Gwolle Guestbook (gwolle-gb) plugin before 2.5.4 for WordPress via the PATH_INFO to wp-admin/index.php | MEDIUM | Oct 2, 2018 |
CVE-2018-17883 | An issue was discovered in Open Ticket Request System (OTRS) 6.0.x before 6.0.12. An attacker could send an e-mail message with a malicious link to an OTRS system or an agent. If a logged-in agent opens this link, it could cause the execution of JavaScript in the context of OTRS. | -- | Apr 17, 2023 |
CVE-2018-17882 | An Integer overflow vulnerability exists in the batchTransfer function of a smart contract implementation for CryptoBotsBattle (CBTB), an Ethereum token. This vulnerability could be used by an attacker to create an arbitrary amount of tokens for any user. | MEDIUM | Mar 22, 2019 |
CVE-2018-17881 | On D-Link DIR-823G 2018-09-19 devices, the GoAhead configuration allows /HNAP1 SetPasswdSettings commands without authentication to trigger an admin password change. | MEDIUM | Oct 3, 2018 |
CVE-2018-17880 | On D-Link DIR-823G 2018-09-19 devices, the GoAhead configuration allows /HNAP1 RunReboot commands without authentication to trigger a reboot. | HIGH | Oct 3, 2018 |
CVE-2018-17879 | An issue was discovered on certain ABUS TVIP cameras. The CGI scripts allow remote attackers to execute code via system() as root. There are several injection points in various scripts. | -- | Oct 26, 2023 |
CVE-2018-17878 | Buffer Overflow vulnerability in certain ABUS TVIP cameras allows attackers to gain control of the program via crafted string sent to sprintf() function. | -- | Oct 26, 2023 |
CVE-2018-17877 | A lottery smart contract implementation for Greedy 599, an Ethereum gambling game, generates a random value that is predictable via an external contract call. The developer used the extcodesize() function to prevent a malicious contract from being called, but the attacker can bypass it by writing the core code in the constructor of their exploit code. Therefore, it allows attackers to always win and get rewards. | MEDIUM | Oct 23, 2018 |
CVE-2018-17876 | A Stored XSS vulnerability has been discovered in the v5.5.0 version of the Coaster CMS product. | MEDIUM | Oct 4, 2018 |
CVE-2018-17875 | A remote code execution issue in the ping command on Poly Trio 8800 5.7.1.4145 devices allows remote authenticated users to execute commands via unspecified vectors. | MEDIUM | Dec 28, 2021 |