Wind River Support Network

Meet the Support Network

Home CVE Database CVE-2024-35986

CVE-2024-35986

Description

In the Linux kernel, the following vulnerability has been resolved: phy: ti: tusb1210: Resolve charger-det crash if charger psy is unregistered The power_supply frame-work is not really designed for there to be long living in kernel references to power_supply devices. Specifically unregistering a power_supply while some other code has a reference to it triggers a WARN in power_supply_unregister(): WARN_ON(atomic_dec_return(&psy->use_cnt)); Folllowed by the power_supply still getting removed and the backing data freed anyway, leaving the tusb1210 charger-detect code with a dangling reference, resulting in a crash the next time tusb1210_get_online() is called. Fix this by only holding the reference in tusb1210_get_online() freeing it at the end of the function. Note this still leaves a theoretical race window, but it avoids the issue when manually rmmod-ing the charger chip driver during development.

Priority: --
CVSS v3: --
Component: linux
Publish Date: May 20, 2024
Related ID: --
CVSS v2: --
Modified Date: May 20, 2024

Find out more about CVE-2024-35986 from the MITRE-CVE dictionary and NIST NVD


Products Affected

Login may be required to access defects or downloads.

Product Name Status Defect Fixed Downloads
Linux
Wind River Linux LTS 17 Requires LTSS -- -- --
Wind River Linux 8 Requires LTSS -- -- --
Wind River Linux 9 Requires LTSS -- -- --
Wind River Linux 7 Requires LTSS -- -- --
Wind River Linux LTS 21 Investigate -- -- --
Wind River Linux LTS 22 Not Vulnerable -- -- --
Wind River Linux LTS 18 Requires LTSS -- -- --
Wind River Linux LTS 19 Investigate -- -- --
Wind River Linux CD release N/A -- -- --
Wind River Linux 6 Requires LTSS -- -- --
Wind River Linux LTS 23 Fixed LIN1023-5765
10.23.30.11 --
VxWorks
VxWorks 7 Not Vulnerable -- -- --
VxWorks 6.9 Not Vulnerable -- -- --
Helix Virtualization Platform Cert Edition
Helix Virtualization Platform Cert Edition Not Vulnerable -- -- --
eLxr
eLxr 12 Fixed -- 6.1.90-1 --

Related Products

Product Name Status Defect Fixed Downloads

Notes
Requires LTSS - customers must have active LTSS (Long Term Security Shield) Support to receive up-to-date information about vulnerabilities that may affect legacy software. Please contact your Wind River account team or see https://docs.windriver.com/bundle/Support_and_Maintenance_Supplemental_Terms_and_Conditions and https://support2.windriver.com/index.php?page=plc for more information.