Wind River Support Network

Meet the Support Network

Home CVE Database CVE-2016-4925

CVE-2016-4925

Description

Receipt of a specifically malformed IPv6 packet processed by the router may trigger a line card reset: processor exception 0x68616c74 (halt) in task: scheduler. The line card will reboot and recover without user interaction. However, additional specifically malformed packets may cause follow-on line card resets and lead to an extended service outage. This issue only affects E Series routers with IPv6 licensed and enabled. Routers not configured to process IPv6 traffic are unaffected by this vulnerability. Juniper SIRT is not aware of any malicious exploitation of this vulnerability. No other Juniper Networks products or platforms are affected by this issue.

Priority: MEDIUM
CVSS v3: 7.5
Component: It doesn't impact WRLinux.
Publish Date: Oct 13, 2017
Related ID: --
CVSS v2: 5.0
Modified Date: Oct 14, 2017

Find out more about CVE-2016-4925 from the MITRE-CVE dictionary and NIST NVD


Products Affected

Login may be required to access defects or downloads.

Product Name Status Defect Fixed Downloads
Linux
Wind River Linux LTS 17 Not Vulnerable -- -- --
Wind River Linux 8 Not Vulnerable -- -- --
Wind River Linux 9 Not Vulnerable -- -- --
Wind River Linux 7 Not Vulnerable -- -- --
Wind River Linux LTS 21 Not Vulnerable -- -- --
Wind River Linux LTS 22 Not Vulnerable -- -- --
Wind River Linux LTS 18 Not Vulnerable -- -- --
Wind River Linux LTS 19 Not Vulnerable -- -- --
Wind River Linux CD release Not Vulnerable -- -- --
Wind River Linux 6 Not Vulnerable -- -- --
Wind River Linux LTS 23 Not Vulnerable -- -- --
VxWorks
VxWorks 7 Not Vulnerable -- -- --
VxWorks 6.9 Not Vulnerable -- -- --
Helix Virtualization Platform Cert Edition
Helix Virtualization Platform Cert Edition Not Vulnerable -- -- --

Related Products

Product Name Status Defect Fixed Downloads

Notes
Requires LTSS - customers must have active LTSS (Long Term Security Shield) Support to receive up-to-date information about vulnerabilities that may affect legacy software. Please contact your Wind River account team or see https://docs.windriver.com/bundle/Support_and_Maintenance_Supplemental_Terms_and_Conditions and https://support2.windriver.com/index.php?page=plc for more information.