Wind River Support Network

HomeDefectsLIN4-19233
Fixed

LIN4-19233 : When rebuild of IMSM volume is started in OROM, rebuild does not proceed when in the Linux OS

Created: Jun 18, 2013    Updated: Mar 10, 2016
Resolved Date: Jun 26, 2013
Found In Version: 4.3
Fix Version: 4.3.0.18
Severity: Severe
Applicable for: Wind River Linux 4
Component/s: Userspace

Description

When rebuild is started in the pre-boot environment within the OROM and the system is rebooted into the OS,  rebuild fails to continue. 

Steps to Reproduce

Steps to Reproduce:
1. Create IMSM RAID5 volume with 3 HDDs
2. Remove one hot swappable HDD from the array 
3. Replace failed HDD with a good HDD (do not add it to container)
4. Restart computer, enter RSTe RAID OROM interface
5. Choose newly added HDD and start rebuild in OROM
5. Boot OS and check RAID status in OS

Actual Results:  
RAID5 volume is in Degraded state in OS. Rebuild has not been started.

Expected Results:  
RAID5 volume is being rebuilt in OS.

Other Downloads


Live chat
Online