Wind River Support Network

HomeDefectsLIN1019-3732
Fixed

LIN1019-3732 : xhci_hcd 0001:00:0c.0: ERROR unknown event type 37

Created: Dec 9, 2019    Updated: Jan 10, 2020
Resolved Date: Jan 7, 2020
Found In Version: 10.19.45.1
Fix Version: 10.19.45.3
Severity: Standard
Applicable for: Wind River Linux LTS 19
Component/s: Kernel

Description

LTP: starting dio25 (diotest6 -b 65536 -i 1000 -o 104857600)
xhci_hcd 0001:00:0c.0: ERROR unknown event type 37
xhci_hcd 0001:00:0c.0: ERROR unknown event type 37
xhci_hcd 0001:00:0c.0: ERROR unknown event type 37
LTP: starting dio26 (diotest6 -b 8192 -v 100)

Steps to Reproduce

$ setup.sh --machines marvell-cn96xx  --distros wrlinux --dl-layers --accept-eula=yes && source environment-setup-x86_64-wrlinuxsdk-linux && source oe-init-build-env build
$ echo KERNEL_FEATURES_append = \\" features/usb/serial-all.scc\\" >> conf/local.conf && echo KERNEL_VERSION_SANITY_SKIP=\\"1\\" >> conf/local.conf && echo IMAGE_FSTYPES += \\" tar.bz2\\"  >> conf/local.conf && echo BB_NUMBER_THREADS ?= \\"24\\" >> conf/local.conf && echo PARALLEL_MAKE ?= \\"-j 24\\" >> conf/local.conf
$ bitbake wrlinux-image-glibc-std

Deploy images and run ltp_dio case group.

https://lkml.org/lkml/2019/1/24/485