The Common Vulnerabilities and Exposures (CVE) project, maintained by the MITRE Corporation, is a list of all standardized names for vulnerabilities and security exposures.
ID | Description | Priority | Modified date |
---|---|---|---|
CVE-2020-12052 | Grafana version < 6.7.3 is vulnerable for annotation popup XSS. | MEDIUM | Apr 29, 2020 |
CVE-2020-12051 | The CentralAuth extension through REL1_34 for MediaWiki allows remote attackers to obtain sensitive hidden account information via an api.php?action=query&meta=globaluserinfo&guiuser= request. In other words, the information can be retrieved via the action API even though access would be denied when simply visiting wiki/Special:CentralAuth in a web browser. | MEDIUM | Apr 22, 2020 |
CVE-2020-12050 | SQLiteODBC 0.9996, as packaged for certain Linux distributions as 0.9996-4, has a race condition leading to root privilege escalation because any user can replace a /tmp/sqliteodbc$$ file with new contents that cause loading of an arbitrary library. | MEDIUM | Apr 30, 2020 |
CVE-2020-12049 | An issue was discovered in dbus >= 1.3.0 before 1.12.18. The DBusServer in libdbus, as used in dbus-daemon, leaks file descriptors when a message exceeds the per-message file descriptor limit. A local attacker with access to the D-Bus system bus or another system service\'s private AF_UNIX socket could use this to make the system service reach its file descriptor limit, denying service to subsequent D-Bus clients. | MEDIUM | Jun 8, 2020 |
CVE-2020-12048 | Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker with access to the network could observe sensitive treatment and prescription data sent between the Phoenix system and the Exalis tool. | MEDIUM | Jun 29, 2020 |
CVE-2020-12047 | The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard-coded credentials. | HIGH | Jun 29, 2020 |
CVE-2020-12046 | Opto 22 SoftPAC Project Version 9.6 and prior. SoftPAC’s firmware files’ signatures are not verified upon firmware update. This allows an attacker to replace legitimate firmware files with malicious files. | LOW | May 15, 2020 |
CVE-2020-12045 | The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials. | HIGH | Jun 29, 2020 |
CVE-2020-12043 | The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP service operating on the WBM remains operational until the WBM is rebooted. | HIGH | Jun 29, 2020 |
CVE-2020-12042 | Opto 22 SoftPAC Project Version 9.6 and prior. Paths specified within the zip files used to update the SoftPAC firmware are not sanitized. As a result, an attacker with user privileges can gain arbitrary file write access with system access. | MEDIUM | May 15, 2020 |
CVE-2020-12041 | The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) telnet Command-Line Interface, grants access to sensitive data stored on the WBM that permits temporary configuration changes to network settings of the WBM, and allows the WBM to be rebooted. Temporary configuration changes to network settings are removed upon reboot. | HIGH | Jun 29, 2020 |
CVE-2020-12040 | Sigma Spectrum Infusion System v\'s6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application layer uses an unauthenticated clear-text communication channel to send and receive system status and operational data. This could allow an attacker that has circumvented network security measures to view sensitive non-private data or to perform a man-in-the-middle attack. | MEDIUM | Jun 29, 2020 |
CVE-2020-12039 | Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v\'s6.x model 35700BAX & Baxter Spectrum Infusion System v\'s8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed. | LOW | Jun 29, 2020 |
CVE-2020-12038 | Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions. | MEDIUM | May 22, 2020 |
CVE-2020-12037 | Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device. | MEDIUM | Jun 29, 2020 |
CVE-2020-12036 | Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device. | MEDIUM | Jun 29, 2020 |
CVE-2020-12035 | Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The PrismaFlex device contains a hard-coded service password that provides access to biomedical information, device settings, calibration settings, and network configuration. This could allow an attacker to modify device settings and calibration. | LOW | Jun 29, 2020 |
CVE-2020-12034 | Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions. | MEDIUM | May 22, 2020 |
CVE-2020-12033 | In Rockwell Automation FactoryTalk Services Platform, all versions, the redundancy host service (RdcyHost.exe) does not validate supplied identifiers, which could allow an unauthenticated, adjacent attacker to execute remote COM objects with elevated privileges. | MEDIUM | Jun 24, 2020 |
CVE-2020-12032 | Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems store device data with sensitive information in an unencrypted database. This could allow an attacker with network access to view or modify sensitive data including PHI. | MEDIUM | Jun 29, 2020 |
CVE-2020-12031 | In all versions of FactoryTalk View SE, after bypassing memory corruption mechanisms found in the operating system, a local, authenticated attacker may corrupt the associated memory space allowing for arbitrary code execution. Rockwell Automation recommends applying patch 1126290. Before installing this patch, the patch rollup dated 06 Apr 2020 or later MUST be applied. 1066644 – Patch Roll-up for CPR9 SRx. | MEDIUM | Jul 24, 2020 |
CVE-2020-12030 | There is a flaw in the code used to configure the internal gateway firewall when the gateway\'s VLAN feature is enabled. If a user enables the VLAN setting, the internal gateway firewall becomes disabled resulting in exposure of all ports used by the gateway. | MEDIUM | Oct 8, 2021 |
CVE-2020-12029 | All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. A remote, unauthenticated attacker may be able to execute a crafted file on a remote endpoint that may result in remote code execution (RCE). Rockwell Automation recommends applying patch 1126289. Before installing this patch, the patch rollup dated 06 Apr 2020 or later MUST be applied. 1066644 – Patch Roll-up for CPR9 SRx. | MEDIUM | Jul 24, 2020 |
CVE-2020-12028 | In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs. | MEDIUM | Jul 24, 2020 |
CVE-2020-12027 | All versions of FactoryTalk View SE disclose the hostnames and file paths for certain files within the system. A remote, authenticated attacker may be able to leverage this information for reconnaissance efforts. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs. | MEDIUM | Jul 24, 2020 |
CVE-2020-12026 | Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. Multiple relative path traversal vulnerabilities exist that may allow a low privilege user to overwrite files outside the application’s control. | MEDIUM | May 8, 2020 |
CVE-2020-12025 | Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02 vulnerable to an xml external entity (XXE) vulnerability, which may allow an attacker to view hostnames or other resources from the program. | MEDIUM | Jul 14, 2020 |
CVE-2020-12024 | Baxter ExactaMix EM 2400 versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 does not restrict access to the USB interface from an unauthorized user with physical access. Successful exploitation of this vulnerability may allow an attacker with physical access to the system the ability to load an unauthorized payload or unauthorized access to the hard drive by booting a live USB OS. This could impact confidentiality and integrity of the system and risk exposure of sensitive information including PHI. | LOW | Jun 29, 2020 |
CVE-2020-12023 | Philips IntelliBridge Enterprise (IBE), Versions B.12 and prior, IntelliBridge Enterprise system integration with SureSigns (VS4), EarlyVue (VS30) and IntelliVue Guardian (IGS). Unencrypted user credentials received in the IntelliBridge Enterprise (IBE) are logged within the transaction logs, which are secured behind the login based administrative web portal. The unencrypted user credentials sent from the affected products listed above, for the purpose of handshake or authentication with the Enterprise Systems, are logged as the payload in IntelliBridge Enterprise (IBE) within the transaction logs. An attacker with administrative privileges could exploit this vulnerability to read plain text credentials from log files. | LOW | Jun 11, 2020 |
CVE-2020-12022 | Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. An improper validation vulnerability exists that could allow an attacker to inject specially crafted input into memory where it can be executed. | HIGH | May 8, 2020 |
CVE-2020-12021 | In OSIsoft PI Web API 2019 Patch 1 (1.12.0.6346) and all previous versions, the affected product is vulnerable to a cross-site scripting attack, which may allow an attacker to remotely execute arbitrary code. | MEDIUM | Jun 24, 2020 |
CVE-2020-12020 | Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13 and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 does not restrict non administrative users from gaining access to the operating system and editing the application startup script. Successful exploitation of this vulnerability may allow an attacker to alter the startup script as the limited-access user. | LOW | Jun 29, 2020 |
CVE-2020-12019 | WebAccess Node Version 8.4.4 and prior is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code. | HIGH | Jun 18, 2020 |
CVE-2020-12018 | Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. An out-of-bounds vulnerability exists that may allow access to unauthorized data. | MEDIUM | May 8, 2020 |
CVE-2020-12017 | GE Grid Solutions Reason RT Clocks, RT430, RT431, and RT434, all firmware versions prior to 08A05. The device’s vulnerability in the web application could allow multiple unauthenticated attacks that could cause serious impact. The vulnerability may allow an unauthenticated attacker to execute arbitrary commands and send a request to a specific URL that could cause the device to become unresponsive. The unauthenticated attacker may change the password of the \'configuration\' user account, allowing the attacker to modify the configuration of the device via the web interface using the new password. This vulnerability may also allow an unauthenticated attacker to bypass the authentication required to configure the device and reboot the system. | HIGH | Jun 8, 2020 |
CVE-2020-12016 | Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account credentials for the ExactaMix operating system. Successful exploitation of this vulnerability may allow an attacker who has gained unauthorized access to system resources, including access to execute software or to view/update files, directories, or system configuration. This could allow an attacker with network access to view sensitive data including PHI. | HIGH | Jun 29, 2020 |
CVE-2020-12015 | A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition due to improper deserialization. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior. | MEDIUM | Jul 17, 2020 |
CVE-2020-12014 | Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. Input is not properly sanitized and may allow an attacker to inject SQL commands. | MEDIUM | May 8, 2020 |
CVE-2020-12013 | A specially crafted WCF client that interfaces to the may allow the execution of certain arbitrary SQL commands remotely. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior. | MEDIUM | Jul 17, 2020 |
CVE-2020-12012 | Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13, and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 have hard-coded administrative account credentials for the ExactaMix application. Successful exploitation of this vulnerability may allow an attacker with physical access to gain unauthorized access to view/update system configuration or data. This could impact confidentiality and integrity of the system and risk exposure of sensitive information including PHI. | LOW | Jun 29, 2020 |
CVE-2020-12011 | A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition or allow remote code execution. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; GenBroker32 version 9.5 and prior. | HIGH | Jul 17, 2020 |
CVE-2020-12010 | Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. Multiple relative path traversal vulnerabilities exist that may allow an authenticated user to use a specially crafted file to delete files outside the application’s control. | MEDIUM | May 8, 2020 |
CVE-2020-12009 | A specially crafted communication packet sent to the affected device could cause a denial-of-service condition due to a deserialization vulnerability. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior. | MEDIUM | Jul 17, 2020 |
CVE-2020-12008 | Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems use cleartext messages to communicate order information with an order entry system. This could allow an attacker with network access to view sensitive data including PHI. | MEDIUM | Jun 29, 2020 |
CVE-2020-12007 | A specially crafted communication packet sent to the affected devices could allow remote code execution and a denial-of-service condition due to a deserialization vulnerability. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior. | HIGH | Jul 17, 2020 |
CVE-2020-12006 | Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. Multiple relative path traversal vulnerabilities exist that may allow a low privilege user to overwrite files outside the application’s control. | HIGH | May 8, 2020 |
CVE-2020-12005 | FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition. | HIGH | Jun 15, 2020 |
CVE-2020-12004 | The affected product lacks proper authentication required to query the server on the Ignition 8 Gateway (versions prior to 8.0.10) and Ignition 7 Gateway (versions prior to 7.9.14), allowing an attacker to obtain sensitive information. | MEDIUM | Jun 9, 2020 |
CVE-2020-12003 | FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to use specially crafted requests to traverse the file system and expose sensitive data on the local hard drive. | MEDIUM | Jun 15, 2020 |
CVE-2020-12002 | Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. Multiple stack-based buffer overflow vulnerabilities exist caused by a lack of proper validation of the length of user-supplied data, which may allow remote code execution. | HIGH | May 8, 2020 |