IDDescriptionPriorityModified date
CVE-2018-8864 In ATI Systems Emergency Mass Notification Systems (HPSS16, HPSS32, MHPSS, and ALERT4000) devices, a missing encryption of sensitive data vulnerability caused by specially crafted malicious radio transmissions may allow an attacker to remotely trigger false alarms. LOW May 26, 2018
CVE-2018-8863 The HTTP header in Philips EncoreAnywhere contains data an attacker may be able to use to gain sensitive information. -- Nov 9, 2023
CVE-2018-8862 In ATI Systems Emergency Mass Notification Systems (HPSS16, HPSS32, MHPSS, and ALERT4000) devices, an improper authentication vulnerability caused by specially crafted malicious radio transmissions may allow an attacker to remotely trigger false alarms. LOW May 26, 2018
CVE-2018-8861 Vulnerabilities within the Philips Brilliance CT kiosk environment (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) could enable a limited-access kiosk user or an unauthorized attacker to break-out from the containment of the kiosk environment, attain elevated privileges from the underlying Windows OS, and access unauthorized resources from the operating system. MEDIUM May 8, 2018
CVE-2018-8860 In Vecna VGo Robot versions prior to 3.0.3.52164, an attacker may be able to capture firmware updates through the adjacent network. LOW May 9, 2018
CVE-2018-8859 Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. An attacker can bypass the required authentication specified in the security configuration file by including extra characters in the directory name when specifying the directory to be accessed. This vulnerability does not affect the i.LON 600 product. HIGH Jul 24, 2018
CVE-2018-8858 If an attacker has access to the firmware from the VGo Robot (Versions 3.0.3.52164 and 3.0.3.53662. Prior versions may also be affected) they may be able to extract credentials. MEDIUM Oct 30, 2018
CVE-2018-8857 Philips Brilliance CT software (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) contains fixed credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. An attacker could compromise these credentials and gain access to the system. HIGH May 8, 2018
CVE-2018-8856 Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data. MEDIUM Sep 27, 2018
CVE-2018-8855 Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. The devices allow unencrypted Web connections by default, and devices can receive configuration and firmware updates by unsecure FTP. HIGH Jul 24, 2018
CVE-2018-8854 Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not properly restrict the size or amount of resources requested or influenced by an actor, which can be used to consume more resources than intended. MEDIUM Sep 27, 2018
CVE-2018-8853 Philips Brilliance CT devices operate user functions from within a contained kiosk in a Microsoft Windows operating system. Windows boots by default with elevated Windows privileges, enabling a kiosk application, user, or an attacker to potentially attain unauthorized elevated privileges in Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior. Also, attackers may gain access to unauthorized resources from the underlying Windows operating system. HIGH May 8, 2018
CVE-2018-8852 Philips e-Alert Unit (non-medical device), Version R2.1 and prior. When authenticating a user or otherwise establishing a new user session, the software gives an attacker the opportunity to steal authenticated sessions without invalidating any existing session identifier. MEDIUM Sep 27, 2018
CVE-2018-8851 Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. The devices store passwords in plaintext, which may allow an attacker with access to the configuration file to log into the SmartServer web user interface. MEDIUM Jul 24, 2018
CVE-2018-8850 Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not validate input properly, allowing an attacker to craft the input in a form that is not expected by the rest of the application. This would lead to parts of the unit receiving unintended input, which may result in altered control flow, arbitrary control of a resource, or arbitrary code execution. HIGH Sep 27, 2018
CVE-2018-8849 Medtronic N'Vision Clinician Programmer 8840 N'Vision Clinician Programmer, all versions, and 8870 N'Vision removable Application Card, all versions does not encrypt PII and PHI while at rest. LOW May 19, 2018
CVE-2018-8848 Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor. MEDIUM Sep 27, 2018
CVE-2018-8847 Eaton 9000X DriveA versions 2.0.29 and prior has a stack-based buffer overflow vulnerability, which may allow remote code execution. HIGH Jul 14, 2018
CVE-2018-8846 Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users. MEDIUM Sep 27, 2018
CVE-2018-8845 In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, a heap-based buffer overflow vulnerability has been identified, which may allow an attacker to execute arbitrary code. HIGH May 17, 2018
CVE-2018-8844 Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request. MEDIUM Sep 27, 2018
CVE-2018-8843 Rockwell Automation Arena versions 15.10.00 and prior contains a use after free vulnerability caused by processing specially crafted Arena Simulation Software files that may cause the software application to crash, potentially losing any unsaved data.. MEDIUM May 14, 2018
CVE-2018-8842 Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to disclosure of personal contact information and application login credentials from within the same subnet. LOW Sep 27, 2018
CVE-2018-8841 In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, an improper privilege management vulnerability may allow an authenticated user to modify files when read access should only be given to the user. MEDIUM May 17, 2018
CVE-2018-8840 A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution. HIGH Apr 20, 2018
CVE-2018-8839 Delta PMSoft versions 2.10 and prior have multiple stack-based buffer overflow vulnerabilities where a .ppm file can introduce a value larger than is readable by PMSoft\'s fixed-length stack buffer. This can cause the buffer to be overwritten, which may allow arbitrary code execution or cause the application to crash. CVSS v3 base score: 7.1; CVSS vector string: AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H. Delta Electronics recommends affected users update to at least PMSoft v2.11, which was made available as of March 22, 2018, or the latest available version. MEDIUM Nov 5, 2019
CVE-2018-8838 A weakness in access controls in CENTUM CS 1000 all versions, CENTUM CS 3000 versions R3.09.50 and earlier, CENTUM CS 3000 Small versions R3.09.50 and earlier, CENTUM VP versions R6.03.10 and earlier, CENTUM VP Small versions R6.03.10 and earlier, CENTUM VP Basic versions R6.03.10 and earlier, Exaopc versions R3.75.00 and earlier, B/M9000 CS all versions, and B/M9000 VP versions R8.01.01 and earlier may allow a local attacker to exploit the message management function of the system. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:H/A:H). MEDIUM Apr 17, 2018
CVE-2018-8837 Processing specially crafted .pm3 files in Advantech WebAccess HMI Designer 2.1.7.32 and prior may cause the system to write outside the intended buffer area and may allow remote code execution. MEDIUM Apr 25, 2018
CVE-2018-8836 Wago 750 Series PLCs with firmware version 10 and prior include a remote attack may take advantage of an improper implementation of the 3 way handshake during a TCP connection affecting the communications with commission and service tools. Specially crafted packets may also be sent to Port 2455/TCP/IP, used in Codesys management software, which may result in a denial-of-service condition of communications with commissioning and service tools. MEDIUM Apr 3, 2018
CVE-2018-8835 Double free vulnerabilities in Advantech WebAccess HMI Designer 2.1.7.32 and prior caused by processing specially crafted .pm3 files may allow remote code execution. MEDIUM Apr 25, 2018
CVE-2018-8834 Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior, CX-Server versions 5.0.22 and prior, Network Configurator versions 3.63 and prior, and Switch Box Utility versions 1.68 and prior, may cause a heap-based buffer overflow. MEDIUM Apr 17, 2018
CVE-2018-8833 Heap-based buffer overflow vulnerabilities in Advantech WebAccess HMI Designer 2.1.7.32 and prior caused by processing specially crafted .pm3 files may allow remote code execution. MEDIUM Apr 25, 2018
CVE-2018-8832 enhavo 0.4.0 has XSS via a user-group that contains executable JavaScript code in the user-group name. The XSS attack launches when a victim visits the admin user group page. LOW Mar 20, 2018
CVE-2018-8831 A Persistent XSS vulnerability exists in Kodi (formerly XBMC) through 17.6 that allows the execution of arbitrary HTML/script code in the context of the victim user's browser via a playlist. MEDIUM Apr 20, 2018
CVE-2018-8828 A Buffer Overflow issue was discovered in Kamailio before 4.4.7, 5.0.x before 5.0.6, and 5.1.x before 5.1.2. A specially crafted REGISTER message with a malformed branch or From tag triggers an off-by-one heap-based buffer overflow in the tmx_check_pretran function in modules/tmx/tmx_pretran.c. HIGH Mar 24, 2018
CVE-2018-8827 The admin web interface on Technicolor MediaAccess TG789vac v2 HP devices with firmware v16.3.7190-2761005-20161004084353 displays unsanitised user input, which allows an unauthenticated malicious user to embed JavaScript into the Log viewer interface via a crafted HTTP Referer header, aka XSS. MEDIUM Jan 3, 2019
CVE-2018-8826 ASUS RT-AC51U, RT-AC58U, RT-AC66U, RT-AC1750, RT-ACRH13, and RT-N12 D1 routers with firmware before 3.0.0.4.380.8228; RT-AC52U B1, RT-AC1200 and RT-N600 routers with firmware before 3.0.0.4.380.10446; RT-AC55U and RT-AC55UHP routers with firmware before 3.0.0.4.382.50276; RT-AC86U and RT-AC2900 routers with firmware before 3.0.0.4.384.20648; and possibly other RT-series routers allow remote attackers to execute arbitrary code via unspecified vectors. HIGH Apr 20, 2018
CVE-2018-8825 Google TensorFlow 1.7 and below is affected by: Buffer Overflow. The impact is: execute arbitrary code (local). Medium Apr 25, 2019
CVE-2018-8824 modules/bamegamenu/ajax_phpcode.php in the Responsive Mega Menu (Horizontal+Vertical+Dropdown) Pro module 1.0.32 for PrestaShop 1.5.5.0 through 1.7.2.5 allows remote attackers to execute a SQL Injection through function calls in the code parameter. HIGH May 9, 2018
CVE-2018-8823 modules/bamegamenu/ajax_phpcode.php in the Responsive Mega Menu (Horizontal+Vertical+Dropdown) Pro module 1.0.32 for PrestaShop 1.5.5.0 through 1.7.2.5 allows remote attackers to execute arbitrary PHP code via the code parameter. HIGH Mar 27, 2018
CVE-2018-8822 Incorrect buffer length handling in the ncp_read_kernel function in fs/ncpfs/ncplib_kernel.c in the Linux kernel through 4.15.11, and in drivers/staging/ncpfs/ncplib_kernel.c in the Linux kernel 4.16-rc through 4.16-rc6, could be exploited by malicious NCPFS servers to crash the kernel or execute code. HIGH Mar 23, 2018
CVE-2018-8821 windrvr1260.sys in Jungo DriverWizard WinDriver 12.6.0 allows attackers to cause a denial of service (BSOD) via a crafted .exe file. HIGH Mar 20, 2018
CVE-2018-8820 An issue was discovered in Square 9 GlobalForms 6.2.x. A Time Based SQL injection vulnerability in the match parameter allows remote authenticated attackers to execute arbitrary SQL commands. It is possible to upgrade access to full server compromise via xp_cmdshell. In some cases, the authentication requirement for the attack can be met by sending the default admin credentials. MEDIUM Mar 28, 2018
CVE-2018-8819 An XXE issue was discovered in Automated Logic Corporation (ALC) WebCTRL Versions 6.0, 6.1 and 6.5. An unauthenticated attacker could enter malicious input to WebCTRL and a weakly configured XML parser will allow the application to disclose full file contents from the underlying web server OS via the X-Wap-Profile HTTP header. MEDIUM Jun 14, 2018
CVE-2018-8817 Wampserver before 3.1.3 has CSRF in add_vhost.php. MEDIUM Mar 25, 2018
CVE-2018-8815 Cross-site scripting (XSS) vulnerability in the gallery function in Alkacon OpenCMS 10.5.3 allows remote attackers to inject arbitrary web script or HTML via a malicious SVG image. LOW Mar 20, 2018
CVE-2018-8814 Cross-site request forgery (CSRF) vulnerability in WolfCMS 0.8.3.1 allows remote attackers to hijack the authentication of users for requests that modify plugin/[pluginname]/settings by crafting a malicious request. MEDIUM Apr 4, 2018
CVE-2018-8813 Open redirect vulnerability in the login[redirect] parameter login functionality in WolfCMS 0.8.3.1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via a malformed URL. MEDIUM Apr 4, 2018
CVE-2018-8812 Rejected reason: DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: CVE-2018-15610. Reason: This candidate is a reservation duplicate of CVE-2018-15610. Notes: All CVE users should reference CVE-2018-15610 instead of this candidate. All references and descriptions in this candidate have been removed to prevent accidental usage Medium May 14, 2019
CVE-2018-8811 ** DISPUTED ** Cross-site request forgery (CSRF) vulnerability in system/workplace/admin/accounts/user_role.jsp in OpenCMS 10.5.3 allows remote attackers to hijack the authentication of administrative users for requests that perform privilege escalation. Note: It is argued that OpenCMS allows only registered users to upload different kind of content artifacts (SVG, .doc, .docx). The uploaded content is stored in the CMS content repository as is. In case of scripts inside an SVG, this may or may not be malicious, there is no way of knowing if the uploaded SVG contains the script for a reason. To exploit the issue, a user must have an account in the CMS as a content manager. MEDIUM Mar 20, 2018
The 'Fixed Release' column is displayed if a single product version is selected from the filter. The fixed release is applicable in cases when the CVE has been addressed and fixed for that product version. Requires LTSS - customers must have active LTSS (Long Term Security Shield) Support to receive up-to-date information about vulnerabilities that may affect legacy software. Please contact your Wind River account team or see https://docs.windriver.com/bundle/Support_and_Maintenance_Supplemental_Terms_and_Conditions and https://support2.windriver.com/index.php?page=plc for more information.